6.1 E3-Pro Assembly Quality Release Flow¶
Source Basis¶
This page is based on notes/odoo-assembly-workflow,md.
Purpose¶
Define the standard quality decision flow for a newly assembled E3-Pro after manufacturing completion.
Standard Location Pattern¶
- input from
WH/Production Output - QA execution in
WH/Quality - released unit moved to
WH/Finished Goods
Quality Checks¶
The note currently specifies these checks:
- visual inspection
- functional testing
- confirm component IDs match
Decision Flow¶
PASS: move the FG serial toWH/Finished GoodsFAIL: route to rework or scrap according to the disposition decision
Expected Result¶
- the FG unit is not saleable before QA
- the release decision is visible in the movement flow
- the quality step confirms both build quality and identity consistency